Міністерство економічного розвитку і торгівлі України

Наказ від 29.12.2014 № 1480

EN 60598-2-24:2013

Luminaires - Part 2-24: Particular requirements - Luminaires with limited surface temperatures

прийнято як національний стандарт
методом «підтвердження» за позначенням

ДСТУ EN 60598-2-24:2014

(EN 60598-2-24:2013, IDT)

Світильники. Частина 2-24. Додаткові вимоги. Світильники з обмеженою температурою поверхонь

 

English version

Luminaires -
Part 2-24: Particular requirements -
Luminaires with limited surface temperatures
(IEC 60598-2-24:2013)

Foreword

The text of document 34D/1094/FDIS, future edition 2 of IEC 60598-2-24, prepared by SC 34D "Luminaires" of IEC/TC 34 "Lamps and related equipment" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60598-2-24:2013.

The following dates are fixed:

latest date by which the document has to be      (dop)         2014-04-24
implemented at national level by
publication of an identical national
standard or by endorsement

latest date by which the national                      (dow)          2016-07-24
standards conflicting with the
document have to be withdrawn

This document supersedes EN 60598-2-24:1998.

EN 60598-2-24:2013 includes the following significant technical changes with respect to
EN 60598-2-24:1998:

a) change of required degree of protection from IP6X to IP4X to harmonize with the international
wiring rules;
b) temperature limits introduced for glass surface of any light source exposed to risk of dust.

This standard is to be read in conjunction with EN 60598-1, Luminaires – Part 1: General requirements and tests.

NOTE In this standard, the following print types are used:

– requirements: in roman type.

– test specifications: in italic type.

– notes: in small roman type.

Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent rights.

This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC).

Endorsement notice

The text of the International Standard IEC 60598-2-24:2013 was approved by CENELEC as a European Standard without any modification.


Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies

Publication
IEC 60364-4-42

Year
-

Title
Low voltage electrical installations -
Part 4-42: Protection for safety - Protection
against thermal effects

EN/HD
HD 60364-4-42

Year
-

IEC 60598-1              -           Luminaires -
                                            Part 1: General requirements and tests                     EN 60598-1     -
ISO 4225                1994        Air quality - General aspects – Vocabulary         

                                           -               -

CONTENTS

24.1 Scope................................................................ 5
24.2 Normative references .......................................... 5
24.3 General test requirements.................................... 5
24.4 Terms and definitions .......................................... 5
24.5 Classification of luminaires .................................. 6
24.6 Marking ............................................................. 6
24.7 Construction ...................................................... 6
24.8 Creepage distances and clearances..................... 7
24.9 Provision for earthing........................................... 7
24.10 Terminals and electrical connections................... 7
24.11 External and internal wiring................................. 7
24.12 Protection against electric shock........................ 7
24.13 Endurance test and thermal test......................... 7
24.13.1 Temperature limits – normal operation............... 7
24.13.2 Temperature limits – abnormal operation .......... 8
24.13.3 Temperature limits – fault conditions ................ 8
24.14 Resistance to dust, solid objects and moisture ... 8
24.15 Insulation resistance and electric strength........... 8
24.16 Resistance to heat, fire and tracking ................... 8
Figure 1 – Symbol for luminaires with
limited surface temperatures .. ...........................

 

.......... 6

 

LUMINAIRES –
Part 2-24: Particular requirements –
Luminaires with limited surface temperatures


24.1 Scope

This part of the IEC 60598 series specifies requirements for luminaires intended for use where the necessity of limited temperature on the outer surface exists, due to the risk of thermal effects, combustion or degradation of materials but where the risk of explosion in the atmosphere does not exist. The luminaires are for use with electric light sources on supply voltages not exceeding 1 000 V.

This standard specifically excludes requirements for luminaires for use in explosive gas atmospheres and explosive dust atmospheres.

24.2 Normative references

The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

IEC 60364-4-42, Low-voltage electrical installations – Part 4-42: Protection for safety – Protection against thermal effects

IEC 60598-1, Luminaires – Part 1: General requirements and test

ISO 4225:1994, Air quality – General aspects – Vocabulary

24.3 General test requirement

The provisions of Section 0 in IEC 60598-1 apply. The tests described in each appropriate section of IEC 60598-1 shall be carried out in the order listed in this standard.

24.4 Terms and definitions

For the purposes of this document, the terms and definitions given in Section 1 of IEC 60598-1 apply, as well as the following apply.

24.4.1
dust
small solid particles in the atmosphere which settle out under their own weight, but which may remain suspended in air for some time (includes dust and grit as defined in ISO 4225) 

24.4.2
explosive gas atmosphere

mixture with air, under atmospheric conditions, of flammable substances in the form of gas or vapour which, after ignition, permits self sustaining flame propagation

[SOURCE: IEC 60050-426:2008, 426-01-07]

24.4.3
explosive dust atmosphere
a mixture with air, under atmospheric conditions, of flammable substances in the form of dust,
fibres or flyings which, after ignition, permits self-sustaining propagation
[SOURCE: IEC 60050-426:2008, 426-01-08]

24.5 Classification of luminaires

Luminaires shall be classified in accordance with the provisions of Section 2 of IEC 60598-1. Additionally luminaires complying with this section are classified suitable for use in locations specified in IEC 60364-4-42 as follows.

a) For use in environments where no unusual accumulation of dust is expected.

b) For use in environments where an accumulation of non-conductive dust on the luminaire
may be expected.

c) For use in environments where an accumulation of conductive dust on the luminaire may be expected.

24.6 Marking

The provisions of Section 3 of IEC 60598-1 apply together with the following requirements.

24.6.1 Luminaires shall be marked with the symbol (see Figure 1). This marking shall be visible and meet the requirements of 3.2 c) of IEC 60598-1.

Figure 1 – Symbol for luminaires with limited surface temperatures

24.6.2 From the manufacturers literature it shall be evident to which location the luminaire is intended in accordance with the luminaires classification as given in 24.5 of this standard.

24.7 Construction

The provisions of Section 4 of IEC 60598-1 apply, together with the requirements of 24.7.1 and 24.7.2 below.

24.7.1 Luminaires shall be provided with an enclosure providing a degree of protection of at least IP4X or in the presence of dust, IP5X or in the presence of conductive dust, IP6X.

For certain locations the international wiring rules may require at least IP5X or IP6X (see  IEC 60364-4-42).

Compliance is checked by inspection.

 

Данний документ, придатний для використання і в повному об'ємі знаходиться в ІДС "Зодчий"

Детальніше про Інформаційно-Довідкову Систему "Зодчий"

Інформаційно-довідкова система (ІДС) «ЗОДЧИЙ» - це база даних нормативно-правових документів у галузі будівництва, створена у відповідності до замовлень Міністерства архітектури України № 29 від 15.02.1994р. і № 43 від 09.03.1994 р. Це найпопулярніший на сьогодні ліцензійний збірник будівельних детальних документів України (зі змінами та доповненнями).
Базові будівельні нормативні документи ІДС "Зодчий" визнані всіма офіційними органи, мають силу печатних офіційних видань БНіП (СНИП), ГОСТ, ДБН, ДСТУ, ВБН (ВСН), ДНАОП, при цьому доступні за ціною та зручніші в зберіганні та використанні.

 

 Ліцензійні програми за ціною виробника

 Для автоматизації визначення вартості будівництва - нового, реконструкції, капітального ремонту та технічного переоснащення Повний набір діючих в Україні будівельних нормативних документів та актів в останній редакції Нормативи і інструменти для впровадження та розрахунку всієї кошторисної і підрядної документації